Martini Mi170 Autoranging Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter

847-775-0640 Call us M-F 9-5:30 CST

Martini Mi170 Autoranging Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter

Product code: 2724
TE-MI-170

Be the first to review this product

Availability: Usually Ships within 24 Hours

$574.95
Reward Points Policy 5,749 AQUAPOINTS
OR
Martini Mi170 Autoranging Conductivity / TDS / NaCl / Temperature Laboratory Bench MeterThis high performance economy microprocessor-based pH/ORP/Temp Bench meter is an ideal tool in schools, laboratories and production plants.It is provided with a series of new diagnostic features which add an entirely new dimension to the measurement of pH, by allowing the user to dramatically improve the reliability of the measurement:

Martini Mi170 Autoranging Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter.

Mi170 measures 4 different parameters - EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature in a variety of ranges.

The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample. All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user.

The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy.

Conductivity readings are performed with the 4-ring probe supplied with the meter. The GLP feature allows users to store and recall data on system status.
PC compatible through an RS232 or USB port.

SPECIFICATIONS
EC Range 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm actual Conductivity*
TDS Range 0.00 to 14.99 mg/l (ppm); 15.0 to 149.9 mg/l (ppm); 150 to 1499 mg/l (ppm); 1.5 to 14.99 g/l (ppt); 15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS* (with 0.80 factor)
NaCl Range 0.0 to 400.0%
Temp Range -20.0 to 120.0°C / -4.0 to 248.0°F
EC Resolution 0.01 µS/cm; 0.1 µS/cm; 1.0 µS/cm; 0.01 mS/cm; 0.1 mS/cm
TDS Resolution 0.01 mg/l; 0.1 mg/l; 1.0 mg/l; 0.01 g/l; 0.1 g/l
NaCl Resolution 0.1%
Temp Resolution 0.1°C / 0.1 °F
EC Accuracy ±1% of reading ±(0.05 µS/cm ro 1 digit)
TDS Accuracy ±1% of reading ±(0.03 mg/l or 1 digit)
NaCl Accuracy ±1% of reading
Temp Accuracy ±0.4°C / ±0.8°F
EC Calibration 1 point slope calibration with 6 memorized solutions (84.0 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
NaCl Calibration 1 point, with MA9066 calibration solution
Temp Calibration 2 points, 0 to 50°C / 32 to 12 °F
Temp. Compensation automatic or manual, from -20.0 to 120.0°C / -4.0 to 248.0°F
Temp. Coefficient selectable from 0.00 to 6.00%/°C (EC and TDS only)
Probe MA813D/1 4-ring probe with built-in temperature sensor (included)
TDS Factor 0.40 to 0.80 (default value is 0.50)
Log on Demand up to 50 samples on each range (EC, TDS, NaCl)
GLP last EC, NaCl calibration data
PC Interface RS232 / USB Opto-isolated
Environment 0 to 50°C / 32 to 122°F; max RH 95%
Power supply 12 VDC power adapter (included)
Dimensions 230 x 160 x 95 mm
Weight 0.9 kg

Questions on Martini Mi170 Autoranging Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter